Minor doc updates
This commit is contained in:
parent
5f5df2ce17
commit
64c7b5dd84
4 changed files with 25 additions and 17 deletions
|
@ -318,6 +318,8 @@ E.g. -X "n=doorbell,m=OOK_PWM,s=400,l=800,r=7000,g=1000,match={24}0xa9878c,repea
|
|||
devices: posts device and sensor info in nested topics
|
||||
The topic string will expand keys like [/model]
|
||||
E.g. -F "mqtt://localhost:1883,user=USERNAME,pass=PASSWORD,retain=0,devices=rtl_433[/id]"
|
||||
With MQTT each rtl_433 instance needs a distinct driver selection. The MQTT Client-ID is computed from the driver string.
|
||||
If you use multiple RTL-SDR, perhaps set a serial and select by that (helps not to get the wrong antenna).
|
||||
Specify InfluxDB 2.0 server with e.g. -F "influx://localhost:9999/api/v2/write?org=<org>&bucket=<bucket>,token=<authtoken>"
|
||||
Specify InfluxDB 1.x server with e.g. -F "influx://localhost:8086/write?db=<db>&p=<password>&u=<user>"
|
||||
Additional parameter -M time:unix:usec:utc for correct timestamps in InfluxDB recommended
|
||||
|
|
|
@ -194,7 +194,7 @@ stop_after_successful_events false
|
|||
|
||||
protocol 1 # Silvercrest Remote Control
|
||||
protocol 2 # Rubicson Temperature Sensor
|
||||
protocol 3 # Prologue Temperature Sensor
|
||||
protocol 3 # Prologue, FreeTec NC-7104, NC-7159-675 temperature sensor
|
||||
protocol 4 # Waveman Switch Transmitter
|
||||
# protocol 6 # ELV EM 1000
|
||||
# protocol 7 # ELV WS 2000
|
||||
|
@ -214,7 +214,7 @@ stop_after_successful_events false
|
|||
# protocol 22 # X10 RF
|
||||
protocol 23 # DSC Security Contact
|
||||
# protocol 24 # Brennenstuhl RCS 2044
|
||||
protocol 25 # GT-WT-02 Sensor
|
||||
protocol 25 # Globaltronics GT-WT-02 Sensor
|
||||
protocol 26 # Danfoss CFR Thermostat
|
||||
protocol 29 # Chuango Security Technology
|
||||
protocol 30 # Generic Remote SC226x EV1527
|
||||
|
@ -234,17 +234,17 @@ stop_after_successful_events false
|
|||
protocol 44 # CurrentCost Current Sensor
|
||||
protocol 45 # emonTx OpenEnergyMonitor
|
||||
protocol 46 # HT680 Remote control
|
||||
protocol 47 # S3318P Temperature & Humidity Sensor
|
||||
protocol 47 # Conrad S3318P, FreeTec NC-5849-913 temperature humidity sensor
|
||||
protocol 48 # Akhan 100F14 remote keyless entry
|
||||
protocol 49 # Quhwa
|
||||
protocol 50 # OSv1 Temperature Sensor
|
||||
protocol 51 # Proove
|
||||
protocol 51 # Proove / Nexa / KlikAanKlikUit Wireless Switch
|
||||
protocol 52 # Bresser Thermo-/Hygro-Sensor 3CH
|
||||
protocol 53 # Springfield Temperature and Soil Moisture
|
||||
protocol 54 # Oregon Scientific SL109H Remote Thermal Hygro Sensor
|
||||
protocol 55 # Acurite 606TX Temperature Sensor
|
||||
protocol 56 # TFA pool temperature sensor
|
||||
protocol 57 # Kedsum Temperature & Humidity Sensor
|
||||
protocol 57 # Kedsum Temperature & Humidity Sensor, Pearl NC-7415
|
||||
protocol 58 # Blyss DC5-UK-WH
|
||||
protocol 59 # Steelmate TPMS
|
||||
protocol 60 # Schrader TPMS
|
||||
|
@ -255,28 +255,28 @@ stop_after_successful_events false
|
|||
protocol 67 # Radiohead ASK
|
||||
protocol 68 # Kerui PIR / Contact Sensor
|
||||
protocol 69 # Fine Offset WH1050 Weather Station
|
||||
protocol 70 # Honeywell Door/Window Sensor
|
||||
protocol 70 # Honeywell Door/Window Sensor, 2Gig DW10/DW11, RE208 repeater
|
||||
protocol 71 # Maverick ET-732/733 BBQ Sensor
|
||||
# protocol 72 # RF-tech
|
||||
protocol 73 # LaCrosse TX141-Bv2, TX141TH-Bv2, TX141-Bv3, TX141W, TX145wsdth sensor
|
||||
protocol 74 # Acurite 00275rm,00276rm Temp/Humidity with optional probe
|
||||
protocol 75 # LaCrosse TX35DTH-IT, TFA Dostmann 30.3155 Temperature/Humidity sensor
|
||||
protocol 76 # LaCrosse TX29IT Temperature sensor
|
||||
protocol 77 # Vaillant calorMatic 340f Central Heating Control
|
||||
protocol 78 # Fine Offset Electronics, WH25, WH24, WH65B, HP1000 Temperature/Humidity/Pressure Sensor
|
||||
protocol 77 # Vaillant calorMatic VRT340f Central Heating Control
|
||||
protocol 78 # Fine Offset Electronics, WH25, WH32B, WH24, WH65B, HP1000 Temperature/Humidity/Pressure Sensor
|
||||
protocol 79 # Fine Offset Electronics, WH0530 Temperature/Rain Sensor
|
||||
protocol 80 # IBIS beacon
|
||||
protocol 81 # Oil Ultrasonic STANDARD FSK
|
||||
protocol 82 # Citroen TPMS
|
||||
protocol 83 # Oil Ultrasonic STANDARD ASK
|
||||
protocol 84 # Thermopro TP11 Thermometer
|
||||
protocol 85 # Solight TE44
|
||||
protocol 85 # Solight TE44/TE66, EMOS E0107T, NX-6876-917
|
||||
protocol 86 # Wireless Smoke and Heat Detector GS 558
|
||||
protocol 87 # Generic wireless motion sensor
|
||||
protocol 88 # Toyota TPMS
|
||||
protocol 89 # Ford TPMS
|
||||
protocol 90 # Renault TPMS
|
||||
protocol 91 # inFactory
|
||||
protocol 91 # inFactory, FreeTec NC-3982-913 temperature humidity sensor
|
||||
protocol 92 # FT-004-B Temperature Sensor
|
||||
protocol 93 # Ford Car Key
|
||||
protocol 94 # Philips outdoor temperature sensor (type AJ3650)
|
||||
|
@ -289,19 +289,19 @@ stop_after_successful_events false
|
|||
# protocol 101 # Dish remote 6.3
|
||||
protocol 102 # SimpliSafe Home Security System (May require disabling automatic gain for KeyPad decodes)
|
||||
protocol 103 # Sensible Living Mini-Plant Moisture Sensor
|
||||
# protocol 104 # Wireless M-Bus, Mode C&T, 100kbps (-f 868950000 -s 1200000)
|
||||
# protocol 105 # Wireless M-Bus, Mode S, 32.768kbps (-f 868300000 -s 1000000)
|
||||
protocol 104 # Wireless M-Bus, Mode C&T, 100kbps (-f 868950000 -s 1200000)
|
||||
protocol 105 # Wireless M-Bus, Mode S, 32.768kbps (-f 868300000 -s 1000000)
|
||||
# protocol 106 # Wireless M-Bus, Mode R, 4.8kbps (-f 868330000)
|
||||
# protocol 107 # Wireless M-Bus, Mode F, 2.4kbps
|
||||
protocol 108 # WS Temperature Sensor
|
||||
protocol 108 # Hyundai WS SENZOR Remote Temperature Sensor
|
||||
protocol 109 # WT0124 Pool Thermometer
|
||||
protocol 110 # PMV-107J (Toyota) TPMS
|
||||
protocol 111 # Emos TTX201 Temperature Sensor
|
||||
protocol 112 # Ambient Weather TX-8300 Temperature/Humidity Sensor
|
||||
protocol 113 # Ambient Weather WH31E Thermo-Hygrometer Sensor, EcoWitt WH40 rain gauge
|
||||
protocol 114 # Maverick et73
|
||||
protocol 115 # Honeywell Wireless Doorbell
|
||||
protocol 116 # Honeywell Wireless Doorbell (FSK)
|
||||
protocol 115 # Honeywell ActivLink, Wireless Doorbell
|
||||
protocol 116 # Honeywell ActivLink, Wireless Doorbell (FSK)
|
||||
# protocol 117 # ESA1000 / ESA2000 Energy Monitor
|
||||
# protocol 118 # Biltema rain gauge
|
||||
protocol 119 # Bresser Weather Center 5-in-1
|
||||
|
|
|
@ -516,7 +516,7 @@ DirecTV RC66RX Remote Control
|
|||
* Eurochron temperature and humidity sensor
|
||||
.TP
|
||||
[ \fB130\fI\fP ]
|
||||
* IKEA Sparsnäs Energy Meter Monitor
|
||||
IKEA Sparsnäs Energy Meter Monitor
|
||||
.TP
|
||||
[ \fB131\fI\fP ]
|
||||
Microchip HCS200 KeeLoq Hopping Encoder based remotes
|
||||
|
@ -768,6 +768,12 @@ The topic string will expand keys like [/model]
|
|||
E.g. \-F "mqtt://localhost:1883,user=USERNAME,pass=PASSWORD,retain=0,devices=rtl_433[/id]"
|
||||
.RE
|
||||
.RS
|
||||
With MQTT each rtl_433 instance needs a distinct driver selection. The MQTT Client\-ID is computed from the driver string.
|
||||
.RE
|
||||
.RS
|
||||
If you use multiple RTL\-SDR, perhaps set a serial and select by that (helps not to get the wrong antenna).
|
||||
.RE
|
||||
.RS
|
||||
Specify InfluxDB 2.0 server with e.g. \-F "influx://localhost:9999/api/v2/write?org=<org>&bucket=<bucket>,token=<authtoken>"
|
||||
.RE
|
||||
.RS
|
||||
|
|
|
@ -338,7 +338,7 @@ static int parse_block2(r_device *decoder, const m_bus_data_t *in, m_bus_block1_
|
|||
b2->CW = b[4]<<8 | b[3];
|
||||
b2->pl_offset = BLOCK1A_SIZE-2 + 5;
|
||||
}
|
||||
// printf("Instantaneous Value: %02x%02x : %f\n",b[9],b[10],((b[10]<<8)|b[9])*0.01);
|
||||
// fprintf(stderr, "Instantaneous Value: %02x%02x : %f\n",b[9],b[10],((b[10]<<8)|b[9])*0.01);
|
||||
}
|
||||
return 0;
|
||||
}
|
||||
|
|
Loading…
Add table
Add a link
Reference in a new issue